Wednesday, November 4, 2009

Cheap UPS Batteray: What You Need to Know About Tune-Ups

Cheap UPS Batteray

Most people know that it is important to get regular vehicle tune-ups. However, most people do not know what exactly is included in a tune-up. This is information of which everyone should be aware because-like it or not-there are some mechanics out there who will try to get away with doing less than they should. If people know what is regularly included in most tune-ups, though, they can keep a watchful eye so as to make certain that all of the steps are completed.

Here is a guideline of what is generally included in most tune-ups. Keep this information in mind when taking any vehicle in for a tune-up.

Typically, a tune-up is defined as a procedure that is designed to inspect and then repair or replace a vehicle's parts that are meant to wear out after time and usage. Additionally, a tune-up is designed to ascertain that vehicle systems are functioning within normal limits. This sounds rather vague, of course. This is because tune-ups are designed differently for each make and model of vehicle because each make and model of vehicle has different components and systems.

However, there are specific items that mechanics do make certain to check in nearly all vehicles. These items are universally checked because they generally need replaced or repaired in all types of automobiles. Here are the items that mechanics usually look into repairing or replacing during tune-ups:

• Oil filter
• Air filter
• Fuel filters
• Spark plugs
• Distributor cap
• Rotor
• Valve-cover gasket
• Positive crankcase ventilation (PVC) valve

Of course, not all vehicles need to have all of these items replaced or repaired. For example, if a car's PVC valve isn't clogged, a mechanic will not replace it during a tune-up.

Aside from checking specific items during a tune-up, mechanics also perform other routine duties. These duties are, again, common to most makes and models of vehicles. Here are the duties most mechanics perform:

• Adjusting the valves
• Topping off all of the fluids
• Checking the battery and cleaning the terminals

Certain cars or vehicles may also require that the mechanic pay specific attention to other issues when performing a tune-up. This is the case with older, rare models of cars that have unique types of engines and also with hybrid vehicles that need attention given to their alternative fuel source systems.

The benefits of getting regular tune-ups for a vehicle are great. Vehicles that get routine tune-ups have better fuel economy, for one thing-which is quite important these days. Just getting a thorough tune-up can improve a vehicle's gas mileage by 4% to 12%. Also, these automobiles tend to have better performance than vehicles that go without tune-ups. Tune-ups also help to prolong a vehicle's driving life.

Some car owners decide to get a tune-up based upon how many miles their vehicle has been driven. These owners often use 30,000 miles as a starting point for tune-ups. It can be a good idea, though, to instead figure out a time for a tune-up based upon gas mileage. When a vehicle's mileage falls below 15%, get a tune-up.

If you are looking for honest advice, prioritized repairs, options on repairs, maximized fuel economy, and a good feeling with who you are doing business with go to http://westsideautopros.com

Article Source: http://EzineArticles.com/?expert=Ron_Haugen

Cheap UPS Batteray: The Basic UPS Guide


Cheap UPS Batteray

It could happen to you at any time, and in a blink of an eye. All it takes is a small spike, surge, brownout, or any other fluctuation in the voltage , and your equipment can be permanently damaged, your data destroyed, and your operating system files corrupted. Faulty electrical power can insidiously wear down your system over a period of time, without you knowing - until - eventually, it fails. One way of avoiding such disaster is to install a UPS. A UPS (Uninterrupted Power Supply) is a power supply that includes a battery to maintain power in the event of a power outage. Most UPS units will also filter and regulate the utility power. A UPS can be used on most electronic equipment, although this article will focus mainly on its use with computers.
There are basically three types of UPSs to choose from. Keep in mind that each manufacturer has their own design and changes. The types are as follows:


1. Offline (Standby) UPS
The standby UPS is the simplest and least expensive UPS design. Getting it's primary power from the AC line (i.e. your outlet), this type of UPS switches over to the backup battery automatically when any drop in voltage is detected. When the power is restored, the UPS then switches back. This "no frill" UPS usually has nothing to regulate the electricity although a few manufacturers may include some sort of line filter.
A "ferroresonant standby" UPS is an improvement on the design of the standby UPS. The ferroresonant UPS uses a ferroresonant transformer to switch from line power to battery power. By using this technology there is a source of stored energy that is used during that fraction of a second while the unit switches between line power and battery power. This was once one of the most common UPS designs, and are still made by some manufacturers. Today, most manufacturers have abandoned this design, claiming that it is inefficient, and favor the "online" UPS for models in the range of 1,000 VA or higher.


2. Line-Interactive UPS
Hailed by some to be the most efficient UPS, the line-interactive UPS is one of the most popular designs used today for computer protection. Although some manufactures sell line-interactive UPSs which are no more than an offline UPS with a regulator added, the basic line-interactive UPS has a bi-directional inverter/charger which is always connected to the output of the UPS, and uses a portion of AC power to keep the battery charged. When the input power fails, the transfer switch disconnects AC input and the battery/inverter provides output power. This gives a faster response to a power failure than an offline UPS.


3. Online UPS
This design is considered to be a "true" UPS. Unlike the other types of UPS, this one uses the battery as its main source of power and the line power is the secondary source of power. When line power goes out the UPS does not have to convert from one power source to another, it just stops charging the battery. This is similar to the way laptops react when they are unplugged from line power. When there isn't any line power the battery will keep powering the system until its stored power is depleted. Since this type of UPS design runs off the battery, the equipment plugged into it will always maintain a constant flow of power. Any surges or brownouts will be taken in at the battery charger and not passed on to the equipment.
These UPSs are often referred to as a "double-conversion" or "double-conversion online" UPS because they convert from AC to DC (battery charger) and then has an inverter to convert DC back to AC, for external devices. Although this method gives a very steady, "clean" flow of power, much of the power is dissipated as heat. This reduces efficiency. In addition, the battery is being used all the time, not just during a power failure like other types of UPSs. To combat this shortcoming, a new design called a "delta-conversion" online UPS was created. In this design, the battery charger is replaced with a delta converter. Instead of providing all of the output from the battery under normal circumstances, some of it is provided directly by the delta converter from the input line power. When there is a power failure, the delta converter stops operating and the unit acts like a regular double-conversion online UPS since the inverter is also running off the battery all the time.
Being more complex, online UPS units generally costs more than offline units. They are generally used only in larger and mission-critical installations.
It is advisable to look over the specifications of the UPS you are considering to buy. If you need more backup time, then you must buy a larger UPS. It must be noted that buying a larger UPS does not always give you more backup time. The size and type of battery used in the UPS has a lot to do with it. UPS batteries are rated in Ah (ampere-hours). Ah represents the amount of energy a battery can hold. This measurement helps determine how long the battery will power the equipment it is used in. The more 'Ah' the longer the run time.
With the prices of UPSs dropping all the time, there is no reason to let your computer go unprotected.

Jonathan Kremer has over 25 years experience in the electrical field. For more tips and articles please visit
    http://www.megavolt.co.il

Article Source: http://EzineArticles.com/?expert=Jonathan_Kremera

Cheap UPS Batteray: UPS Battery Set Sizing For Protracted Mains Power Supply Failures

Cheap UPS Batteray

The batteries within an uninterruptible power supply (UPS) are the heart and lungs of its ability to ride through short duration interruptions, keep loads up and running whilst another source or back up power (such as diesel generator) starts up, or to power through automatic shutdown routines.

UPS batteries must be sized to provide a specified runtime, usually measured in minutes or hours, at a specific Watts, kW or MV load. These load-specific factors are incorporated into a battery sizing algorithm that also takes into account a number of criteria such as ambient temperature and the inverter and system efficiencies of the uninterruptible power supply to which they are applicable.

Whilst battery manufacturers provide discharge curves and tables to assist selection, expert UPS manufacturers utilise bespoke battery sizing software programs designed around their own products' characteristics. Battery packs also tend to be uniform, based around particular types and ranges of battery and manufacturers' own battery cabinets or stands.

The uninterruptible power supply and battery set combination in a solution will be the nearest matching the calculated load. For example, for a total load (including UPS losses) of 20kW, the nearest matching UPS is a 30kVA/24kW system. Provision of a runtime of 30 minutes in this scenario would require the nearest battery option to be, say, a 38Ah battery set, which would provide 25 minutes at 24kW or 33 minutes at 20kW.

Several factors must be considered when sizing a battery set for an uninterruptible power supply. In particular, site power history is important in determining the depth, frequency and likelihood of mains power failures. The size of critical loads needs to be determined. If there is a maintained standby generator on site, this needs to be taken into consideration. How much runtime is needed to cover load shedding and/or an orderly shutdown? Thought must be be given to the immediate environment; how much available floor and rack space is there, for example, and is it a hot, humid environment or a cold, dry one? Cost implications also have to be factored in, particularly in a tight economic climate where cost-reduction is a must. What is the comparative cost, for example, of installing a number of battery strings to achieve particular runtime duration verses an individual standby generator or fuel cell?

Comparisons between runtime performances of different uninterruptible power supply manufacturers can be misleading. Firstly, comparing battery runtime performance between them is difficult without a common basis. The best solution is to ensure all runtimes are quoted using the same formula - load/Watt ratings and load power factors. An example could be: a 10kVA UPS supporting an 8kW load at 0.8pF, the runtime from a 12Ah internal battery set would be 14 minutes. However, at 75 percent load (6kW) and 0.6pF, the same UPS would provide almost 20 minutes of runtime.

It is possible to estimate battery set sizing, which may be useful for budgetary purposes at the specification stage of a power protection project, but as it is so critical to the overall performance and resilience of the uninterruptible power supply system, battery set sizing at the design stage should be carried out by industry professionals to achieve accurate and reliable ratings.

Robin Koffler is the co-author of The Power Protection Blog and the General Manager of Riello UPS Ltd, the UK subsidiary of Riello UPS (RPS S.p.A). For more information visit the Riello UPS - uninterruptible power supplies website.

Article Source: http://EzineArticles.com/?expert=Robin_Koffler